Sundance Spas Optima 880
Manufacture date is not readable on the data plate, so unit age cannot be established. Spa/hot tub warranties are commonly limited or voided when the unit is placed in commercial or rental service; no fetched source documented this for this specific model, so the owner must verify against their own warranty document before assuming any coverage.
Documented instruction: before testing anything, confirm that water is visibly moving in the spa, and never test the heater without confirmed water flow. If no water movement is visible, stop and report to the owner rather than energizing or testing the heater. [3]
Documented test for the FLO error: if the error disappears with the filter out, the filter is clogged; if it stays, the next documented items to check are the flow switch or the heater circulation pump (those checks are not owner steps). [2]
| Code | Documented meaning | Documented action | Who | Why shown | Source |
|---|---|---|---|---|---|
| FLO ✓ | Codes such as FLO, FL, or three blinking dots all indicate insufficient water flow through the heater. | Confirm water is visibly moving in the spa; do not test the heater without confirmed water flow. Documented next checks are the pressure/flow switch test and, if bypassing the switch clears the error, replacing the switch or cable; if not, the circuit board is the likely cause. These checks are service work, not owner steps. | Technician | This is the exact code reported as showing on the unit's panel (FLO), and it is documented as an insufficient-flow-through-heater indication for Sundance spas. | dealer [3] |
Manufacture date is not readable and the serial is not readable, so no age can be calculated as of 2026-08-18. Age of unit: unknown.